DVTOC for MVS3.8J / Hercules                                               
============================                                               


Date: 02/10/2022  Release V0R9M00  **INITIAL software distribution

*  Author:  Larry Belmontes Jr.
*           https://ShareABitofIT.net/DVTOC-in-MVS38J
*           Copyright (C) 2020-2022  Larry Belmontes, Jr.


---------------------------------------------------------------------- 
|    DVTOC        I n s t a l l a t i o n   R e f e r e n c e        | 
---------------------------------------------------------------------- 

   The approach for this installation procedure is to transfer the
distribution content from your personal computing device to MVS with
minimal JCL and to continue the installation procedure using supplied
JCL from the MVS CNTL data set under TSO.                         

   Below are descriptions of ZIP file content, pre-installation
requirements (notes, credits) and installation steps.
 
Good luck and enjoy this software as added value to MVS 3.8J!
-Larry Belmontes



---------------------------------------------------------------------- 
|    DVTOC        C h a n g e   H i s t o r y                        | 
---------------------------------------------------------------------- 
*
*  MM/DD/CCYY Version  Change Description
*  ---------- -------  -----------------------------------------------
*  02/10/2022 0.9.00   - Initial version released to MVS 3.8J
*                        hobbyist public domain
*
*  08/10/2020 0.5.00   Initial prototyping and development
*                      w ISPF 2.x
*
*
======================================================================
* I. C o n t e n t   o f   Z I P   F i l e                           |
======================================================================

o  $INST00.JCL          Define Alias for HLQ DVTOC in Master Catalog
 
o  $INST01.JCL          Load CNTL data set from distribution tape
 
o  $RECVXMI.JCL         Receive XMI SEQ to MVS PDSs                  
 
o  DVTOC.V0R9M00.HET    Hercules Emulated Tape (HET) multi-file volume
                        with VOLSER of VS0900 containing software  
                        distribution.
 
o  DVTOC.V0R9M00.XMI    XMIT file containing software distribution.
 
o  DSCLAIMR.TXT         Disclaimer
 
o  PREREQS.TXT          Required user-mods 
 
o  README.TXT           This File                                              
 
 
Note:   ISPF v2.1 or higher must be installed under MVS3.8J TSO             
-----   including associated user-mods per ISPF Installation Pre-reqs.
 
Note:   VTOC (TSO CP) is a pre-requisite for this install
-----   and is available on MVS3.8J TK3 and TK4- systems.          
        Various versions of VTOC are available from CBT website. 
        More information at:
        https://www.cbttape.org/cbtdowns.htm
        - or -                                                  
        may be downloaded in a MVS 3.8J install-ready format from
        Jay Moseley's site:
        http://www.jaymoseley.com/hercules/cbt_ware/vtoc.htm
 
Credit: TSO CP, VTOC, is authored by R. L. Miller.  
------- More information at:
        https://www.cbttape.org/cbtdowns.htm  FILE #112
 
Note:   PRINTOFF (TSO CP) is a pre-requisite for this install
-----   and may be available on MVS3.8J TK3 and TK4- systems.          
        More information at:
        https://www.cbttape.org/cbtdowns.htm  FILE #325 
        - or -                                                  
        may be downloaded in a MVS 3.8J install-ready format from
        Jay Moseley's site:
        http://www.jaymoseley.com/hercules/cbt_ware/printoff.htm
 
Note:   SCRATCH, CATLG, UNCATLG are pre-prequistes for this install
-----   and may be available on MVS 3.8J TK3 and TK4- systems.
        More information at:
        https://www.cbttape.org/cbtdowns.htm  as FILE #163
        - or -                                                  
        may be downloaded in a MVS 3.8J install-ready format from
        Jay Moseley's site:
        http://www.jaymoseley.com/hercules/cbt_ware/catlg.htm
 
Credit: TSO CP, CATLG, while also supports UNCATLG and SCRATCH,
------- is authored by Dave Phillips. 
        More information at:
        https://www.cbttape.org/cbtdowns.htm  FILE #163
 
Note:   INSTREAM (TSO CP) is a are pre-prequiste for this install
-----   and may be available on MVS 3.8J TK3 and TK4- systems.
        More information at:
        https://www.cbttape.org/cbtdowns.htm  as FILE #300
        - or -                                                  
        may be downloaded in a MVS 3.8J install-ready format from
        Jay Moseley's site:
        http://www.jaymoseley.com/hercules/cbt_ware/instream.htm
 
Credit: TSO CP, INSTREAM, originally authored by Bill Godfrey. 
------- More information at:
        https://www.cbttape.org/cbtdowns.htm  FILE #163
 
Note:   DELETE (TSO CP) is a are pre-prequiste for this install
-----   and available on MVS 3.8J TK3 and TK4- systems.
 
Note:   RENAME (TSO CP) is a are pre-prequiste for this install
-----   and available on MVS 3.8J TK3 and TK4- systems.
 
Note:   The SHRABIT.MACLIB macro PDS must be installed as a pre-requisite.
-----   For convenience purposes, a current version is included.
        Current version can be downloaded and more information at:
        https://www.shareabitofit.net/shrabit-maclib-in-mvs-3-8j/

Note:   CUTIL00 is a TSO utility for CLIST variables and           
-----   is a pre-requisite for this install.  
        Current version can be downloaded and more information at:
        https://www.shareabitofit.net/cutil00-for-mvs-3-8j/    

Note:   LISTDSJ, alias LISTDSI, is a LISTDSI-like program that creates CLIST
-----   variables for some dataset attributes and is a pre-requisite for   
        this install.        
        Current version can be downloaded and more information at:
        https://www.shareabitofit.net/listdsj-for-mvs-3-8j/
 
Note:   CLOGIT performs transaction logging and must be installed as a
-----   pre-requesite.
        Current version can be downloaded and more information at:
        https://www.shareabitofit.net/clglst-in-mvs38j/    

Note:   DSCOPY allows copying of sequential or partitioned data sets and
-----   must be installed as a pre-requisite.
        Current version can be downloaded and more information at:
        https://www.shareabitofit.net/dscopy-in-mvs38j/
 
Note:   DFSPC displays volume free space for all online DASD. 
-----   Optional, but it is an option from the VTOC Utility menu.
        Current version can be downloaded and more information at:
        https://www.shareabitofit.net/dfspc-in-mvs38j/
 
Note:   DUCBD display UCB information from MVS 3.8J. 
-----   Optional, but it is an option from the VTOC Utility menu.
        Current version can be downloaded and more information at:
        https://www.shareabitofit.net/ducbd-in-mvs38j/
 
Note:   DALCDS displays TSO session DD/DSN allocations.
-----   Optional, but it is an option from the VTOC Utility menu.
        Current version can be downloaded and more information at:
        More information at:
        https://www.shareabitofit.net/dalcds-in-mvs38j/
 
 
======================================================================
* II. P r e - i n s t a l l a t i o n   R e q u i r e m e n t s      |
======================================================================

o  The Master Catalog password may be required for some installation
   steps. 
 
o  Tape files use device 480.
 
o  As default, DASD files will be loaded to VOLSER=MVSDLB, type 3350 device.
    
   Below is a DATASET List after tape distribution load for reference purposes:
    
   DATA-SET-NAME------------------------------- VOLUME ALTRK USTRK ORG FRMT % XT
   DVTOC.V0R9M00.ASM                            MVSDLB    30    17 PO  FB  56  1
   DVTOC.V0R9M00.CLIST                          MVSDLB     2     1 PO  FB  50  1
   DVTOC.V0R9M00.CNTL                           MVSDLB    20     8 PO  FB  40  1
   DVTOC.V0R9M00.HELP                           MVSDLB     2     1 PO  FB  50  1
   DVTOC.V0R9M00.ISPF                           MVSDLB    25    17 PO  FB  68  1
   DVTOC.V0R9M00.MACLIB                         MVSDLB     6     5 PO  FB  83  1
   **END**    TOTALS:      85 TRKS ALLOC        49 TRKS USED       6 EXTENTS    
    
   Confirm the TOTAL track allocation is available on MVSDLB.                 
    
   Note: A different DASD device type may be used to yield
         different usage results.
 
o  TSO user-id with sufficient access rights to update SYS2.CMDPROC,  
   SYS2.CMDLIB, SYS2.HELP, SYS2.LINKLIB and/or ISPF libraries.
 
o  For installations with a security system (e.g. RAKF), you MAY need to
   insert additional JOB statement information.
    
   //         USER=???????,PASSWORD=????????
 
o  Names of ISPCLIB (Clist), ISPMLIB (Message), ISPLLIB (Load) and/or 
   ISPPLIB (Panel) libraries.
 
o  Download ZIP file to your PC local drive.    
 
o  Unzip the downloaded file into a temp directory on your PC device.
  
o  Install pre-requisite (if any) software and/or user modifications.
  
 
                                                
======================================================================
* III. I n s t a l l a t i o n   S t e p s                           |
======================================================================
                                                
+--------------------------------------------------------------------+
| Step 1. Define Alias for HLQ DVTOC in MVS User Catalog             |
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($INST00)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC000 JOB (SYS),'Def DVTOC Alias',      <-- Review and Modify 
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC in MVS3.8J TSO / Hercules                     *
//* *  JOB: $INST00  Define Alias for HLQ DVTOC            *
//* *  Note: The master catalog password will be required  *
//* -------------------------------------------------------*
//DEFALIAS EXEC PGM=IDCAMS 
//SYSPRINT DD  SYSOUT=*
//SYSIN    DD  *
 PARM GRAPHICS(CHAIN(SN))
 LISTCAT ALIAS  ENT(DVTOC) 
 
 IF LASTCC NE 0 THEN -
    DEFINE ALIAS(NAME(DVTOC) RELATE(SYS1.UCAT.MVS))                          
/*                                                                      
//
______________________________________________________________________
Figure 1: $INST00 JCL
 
 
    a) Copy and paste the above JCL to a PDS member, update JOB 
       statement to conform to your installation standard.             
 
    b) Submit the job.                                  
 
    c) Review job output for successful DEFINE ALIAS.
 
    Note: When $INST00 runs for the first time,
          Job step DEFALIAS returns RC=0004 due to LISTCAT ALIAS function
          completing with condition code of 4 and DEFINE ALIAS function 
          completing with condition code of 0.
           
    Note: When $INST00 runs after the ALIAS is defined,
          Job step DEFALIAS returns RC=0000 due to LISTCAT ALIAS function
          completing with condition code of 0 and DEFINE ALIAS 
          function being bypassed.
           
 
+--------------------------------------------------------------------+
| Step 2. Determine software installation source                     |
+--------------------------------------------------------------------+
|         HET or XMI ?                                               |
+--------------------------------------------------------------------+
 
 
    a) Software can be installed from two sources, HET or XMI.    
          
       - For tape installation (HET), proceed to STEP 4. ****     
          
         or
          
       - For XMIT installation (XMI), proceed to next STEP.     
 
 
+--------------------------------------------------------------------+
| Step 3. Load XMIPDS data set from XMI SEQ file                     |
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($RECVXMI)                   |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//RECV000A JOB (SYS),'Receive DVTOC XMI',        <-- Review and Modify
//             CLASS=A,MSGCLASS=X,REGION=0M,     <-- Review and Modify
//             MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  JOB: $RECVXMI  Receive Application XMI Files        *
//* -------------------------------------------------------*
//RECV     PROC HLQ=DVTOC,VRM=V0R9M00,TYP=XXXXXXXX,
//             DSPACE='(TRK,(10,05,40))',DDISP='(,CATLG,DELETE)',
//             DUNIT=3350,DVOLSER=MVSDLB         <-- Review and Modify
//*
//RECV370  EXEC PGM=RECV370
//STEPLIB  DD  DSN=SYS2.LINKLIB,DISP=SHR         <-- Review and Modify
//RECVLOG  DD  SYSOUT=*
//XMITIN   DD  DISP=SHR,DSN=&&XMIPDS(&TYP)
//SYSPRINT DD  SYSOUT=*
//SYSUT1   DD  DSN=&&SYSUT1,
//   UNIT=SYSALLDA,SPACE=(CYL,(10,05)),DISP=(,DELETE,DELETE) 
//SYSUT2   DD  DSN=&HLQ..&VRM..&TYP,DISP=&DDISP,
//   UNIT=&DUNIT,SPACE=&DSPACE,VOL=SER=&DVOLSER
//SYSIN    DD  DUMMY
//SYSUDUMP DD  SYSOUT=*
//         PEND
//* RECEIVE XMIPDS TEMP                                       
//XMIPDS   EXEC RECV,TYP=XMIPDS,DSPACE='(CYL,(10,05,10),RLSE)' 
//RECV370.XMITIN DD  DISP=SHR,DSN=your.transfer.xmi    <-- XMI File 
//RECV370.SYSUT2   DD  DSN=&&XMIPDS,DISP=(,PASS), 
//   UNIT=SYSDA,SPACE=&DSPACE
//* RECEIVE CNTL, HELP, CLIST, ISPF, ASM, MACLIB
//ASM      EXEC RECV,TYP=ASM,DSPACE='(TRK,(30,10,20))'
//CLIST    EXEC RECV,TYP=CLIST,DSPACE='(TRK,(02,02,02))'
//CNTL     EXEC RECV,TYP=CNTL,DSPACE='(TRK,(20,10,10))'
//HELP     EXEC RECV,TYP=HELP,DSPACE='(TRK,(02,02,02))'
//ISPF     EXEC RECV,TYP=ISPF,DSPACE='(TRK,(25,05,20))'
//MACLIB   EXEC RECV,TYP=MACLIB,DSPACE='(TRK,(06,02,02))'
//
______________________________________________________________________
Figure 2: $RECVXMI.JCL
 
 
    a) Transfer DVTOC.V0R9M00.XMI to MVS using your 3270 emulator.
       
       Make note of the DSN assigned on MVS transfer.       
       
       Use transfer IND$FILE options:                   
       
          NEW BLKSIZE=3200 LRECL=80 RECFM=FB     
             
       Ensure the DSN on MVS exists with the correct DCB information:
       
          ORG=PS BLKSIZE=3200 LRECL=80 RECFM=FB     
       
          
    b) Copy and paste the above JCL to a PDS member, update JOB 
       statement to conform to your installation standard.
 
       Review JCL and apply any modifications per your installation 
       including the DSN assigned during the transfer above for
       the XMI file.
 
    d) Submit the job.                                              
 
    e) Review job output for successful load of the following PDSs:
 
       DVTOC.V0R9M00.ASM   
       DVTOC.V0R9M00.CLIST 
       DVTOC.V0R9M00.CNTL  
       DVTOC.V0R9M00.HELP  
       DVTOC.V0R9M00.ISPF  
       DVTOC.V0R9M00.MACLIB
 
    f) Subsequent installation steps will be submitted from members
       contained in the CNTL data set.
 
    g) Proceed to STEP 6.   ****
 
 
+--------------------------------------------------------------------+
| Step 4. Load CNTL data set from distribution tape                  |
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($INST01)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC001 JOB (SYS),'Install CNTL PDS',     <-- Review and Modify
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC for MVS3.8J TSO / Hercules                    *
//* *  JOB: $INST01  Load CNTL PDS from distribution tape  *
//* *  Note: Uses tape drive 480                           *
//* -------------------------------------------------------*
//LOADCNTL PROC HLQ=DVTOC,VRM=V0R9M00,TVOLSER=VS0900,      
//   TUNIT=480,DVOLSER=MVSDLB,DUNIT=3350     <-- Review and Modify
//LOAD001  EXEC PGM=IEBCOPY                                           
//SYSPRINT DD  SYSOUT=*                                              
//INCNTL   DD  DSN=&HLQ..&VRM..CNTL.TAPE,UNIT=&TUNIT,
//             VOL=SER=&TVOLSER,DISP=OLD,LABEL=(1,SL)                 
//CNTL     DD  DSN=&HLQ..&VRM..CNTL,
//             UNIT=&DUNIT,VOL=SER=&DVOLSER,
//             SPACE=(TRK,(20,10,10)),DISP=(,CATLG),
//             DCB=(RECFM=FB,LRECL=80,BLKSIZE=3600) 
//         PEND                                                     
//STEP001  EXEC LOADCNTL                     Load CNTL PDS
//SYSIN    DD  *                                                        
    COPY INDD=INCNTL,OUTDD=CNTL 
//                                                                  
______________________________________________________________________
Figure 3: $INST01 JCL
 
 
    a) Before submitting the above job, the distribution tape   
       must be made available to MVS by issuing the following
       command from the Hercules console:
 
       DEVINIT 480 X:\dirname\DVTOC.V0R9M00.HET READONLY=1
 
       where X:\dirname is the complete path to the location
       of the Hercules Emulated Tape file. 
 
    b) Issue the following command from the MVS console to vary
       device 480 online:
 
       V 480,ONLINE
 
    c) Copy and paste the above JCL to a PDS member, update JOB 
       statement to conform to your installation standard.
 
       Review JCL and apply any modifications per your installation.
 
    d) Submit the job.                                              
 
    e) Review job output for successful load of the CNTL data set.
 
    f) Subsequent installation steps will be submitted from members
       contained in the CNTL data set.
 
 
+--------------------------------------------------------------------+
| Step 5. Load Other data sets from distribution tape                |
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($INST02)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC002 JOB (SYS),'Install Other PDSs',   <-- Review and Modify
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC for MVS3.8J TSO / Hercules                    *
//* *  JOB: $INST02  Load other PDS from distribution tape *
//* *  Tape Volume:  File 1 - CNTL                         *
//* *                File 2 - CLIST                        *
//* *                File 3 - HELP                         *
//* *                File 4 - ISPF                         *
//* *                File 5 - ASM                          *
//* *                File 6 - MACLIB                       *
//* *  Note: Default TAPE=480, DASD=3350 on MVSDLB         *
//* -------------------------------------------------------*
//LOADOTHR PROC HLQ=DVTOC,VRM=V0R9M00,TVOLSER=VS0900,            
//   TUNIT=480,DVOLSER=MVSDLB,DUNIT=3350     <-- Review and Modify
//LOAD02   EXEC PGM=IEBCOPY                                           
//SYSPRINT DD  SYSOUT=*                                              
//INCLIST  DD  DSN=&HLQ..&VRM..CLIST.TAPE,UNIT=&TUNIT,
//             VOL=SER=&TVOLSER,DISP=OLD,LABEL=(2,SL)                   
//INHELP   DD  DSN=&HLQ..&VRM..HELP.TAPE,UNIT=&TUNIT,
//             VOL=SER=&TVOLSER,DISP=OLD,LABEL=(3,SL)                   
//INISPF   DD  DSN=&HLQ..&VRM..ISPF.TAPE,UNIT=&TUNIT,
//             VOL=SER=&TVOLSER,DISP=OLD,LABEL=(4,SL)                   
//INASM    DD  DSN=&HLQ..&VRM..ASM.TAPE,UNIT=&TUNIT,
//             VOL=SER=&TVOLSER,DISP=OLD,LABEL=(5,SL)                   
//INMACLIB DD  DSN=&HLQ..&VRM..MACLIB.TAPE,UNIT=&TUNIT,
//             VOL=SER=&TVOLSER,DISP=OLD,LABEL=(6,SL)   
//CLIST    DD  DSN=&HLQ..&VRM..CLIST,UNIT=&DUNIT,VOL=SER=&DVOLSER,
//             SPACE=(TRK,(02,02,02)),DISP=(,CATLG),
//             DCB=(RECFM=FB,LRECL=80,BLKSIZE=3600) 
//HELP     DD  DSN=&HLQ..&VRM..HELP,UNIT=&DUNIT,VOL=SER=&DVOLSER,
//             SPACE=(TRK,(02,02,02)),DISP=(,CATLG),
//             DCB=(RECFM=FB,LRECL=80,BLKSIZE=3600) 
//ISPF     DD  DSN=&HLQ..&VRM..ISPF,UNIT=&DUNIT,VOL=SER=&DVOLSER,
//             SPACE=(TRK,(25,05,10)),DISP=(,CATLG),
//             DCB=(RECFM=FB,LRECL=80,BLKSIZE=3600) 
//ASM      DD  DSN=&HLQ..&VRM..ASM,UNIT=&DUNIT,VOL=SER=&DVOLSER,
//             SPACE=(TRK,(30,10,10)),DISP=(,CATLG),
//             DCB=(RECFM=FB,LRECL=80,BLKSIZE=3600) 
//MACLIB   DD  DSN=&HLQ..&VRM..MACLIB,UNIT=&DUNIT,VOL=SER=&DVOLSER,
//             SPACE=(TRK,(06,02,02)),DISP=(,CATLG),
//             DCB=(RECFM=FB,LRECL=80,BLKSIZE=3600)
//         PEND                                                         
//*
//STEP001  EXEC LOADOTHR                     Load ALL other PDSs
//SYSIN    DD  *                                                        
    COPY INDD=INCLIST,OUTDD=CLIST
    COPY INDD=INHELP,OUTDD=HELP
    COPY INDD=INISPF,OUTDD=ISPF
    COPY INDD=INASM,OUTDD=ASM
    COPY INDD=INMACLIB,OUTDD=MACLIB
//                                                                  
______________________________________________________________________
Figure 4: $INST02 JCL
 
 
    a) Member $INST02 installs remaining data sets from distribution
       tape.                                 
 
    b) Review and update JOB statement and other JCL to conform to your
       installation standard.                                       
 
    c) Before submitting the above job, the distribution tape   
       must be made available to MVS by issuing the following
       command from the Hercules console:
 
       DEVINIT 480 X:\dirname\DVTOC.V0R9M00.HET READONLY=1
 
       where X:\dirname is the complete path to the location
       of the Hercules Emulated Tape file. 
 
    d) Issue the following command from the MVS console to vary
       device 480 online:
 
       V 480,ONLINE
 
    e) Submit the job.
 
    f) Review job output for successful loads.  
 
 
+--------------------------------------------------------------------+
| Step 6. FULL or UPGRADE Installation                               |
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($UP0900)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC00U JOB (SYS),'Upgrade DVTOC',        <-- Review and Modify 
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC in MVS3.8J TSO / Hercules                     *
//* *                                                      *
//* *  JOB: $UP0900  Upgrade DVTOC software                *
//* *       Upgrade from release VxRxMxx                   *
//* *                                                      *
//* *       - No upgrade! INITIAL distribution             *
//* *                                                      *
//* -------------------------------------------------------*
//*
//UP00000  EXEC PGM=IEFBR14
//SYSPRINT DD  SYSOUT=*
// 
______________________________________________________________________
Figure 5: $UP0900.JCL  Upgrade from previous version to V0R9M00
 
    a) If this is the INITIAL software distribution, proceed to STEP 7.
 
    b) This software may be installed in FULL or UPGRADE from a
       prior version.
 
    Note:  If the installed software version is customized, a manual
    -----  review and evaluation is suggested to properly incorporate
           customizations into this software distribution before
           proceeding with the installation.
 
           Refer to the $UPvrmm.JCL members for upgraded software
           components being installed.
 
 
    c) If a FULL install of this software distribution is elected   
       regardless of previous version installed on your system,
       proceed to STEP 7.
 
    d) If this is an UPGRADE from the PREVIOUS version,       
       execute the below JCL based on current installed version:  
 
       - V0R9M00 is initial release, thus, no updates available!
 
 
    d) After upgrade is applied, proceed to validation, STEP 11.
 
 
+--------------------------------------------------------------------+
| Step 7. Install TSO parts                                          |
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($INST03)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC003 JOB (SYS),'Install TSO Parts',    <-- Review and Modify
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC for MVS3.8J TSO / Hercules                    *
//* *                                                      *
//* *  JOB: $INST03  Install TSO parts                     *
//* *                                                      *
//* *  Note: Duplicate members are over-written.           *
//* -------------------------------------------------------*
//STEP001  EXEC PGM=IEBCOPY                                           
//SYSPRINT DD  SYSOUT=*                                              
//INCLIST  DD  DSN=DVTOC.V0R9M00.CLIST,DISP=SHR            
//INHELP   DD  DSN=DVTOC.V0R9M00.HELP,DISP=SHR             
//OUTCLIST DD  DSN=SYS2.CMDPROC,DISP=SHR                               
//OUTHELP  DD  DSN=SYS2.HELP,DISP=SHR
//SYSIN    DD  *                                                        
    COPY INDD=((INCLIST,R)),OUTDD=OUTCLIST
    SELECT MEMBER=NO#MBR#                    /*dummy entry no mbrs! */
    COPY INDD=((INHELP,R)),OUTDD=OUTHELP
    SELECT MEMBER=NO#MBR#                    /*dummy entry no mbrs! */
/*                                                                  
//
______________________________________________________________________
Figure 6: $INST03 JCL
 
 
    a) Member $INST03 installs TSO component(s).
 
       Note:  If no TSO components are included for this distribution,
       -----  RC = 4 is returned by the corresponding IEBCOPY step.
 
    b) Review and update JOB statement and other JCL to conform to your
       installation standard.                                       
 
    c) Submit the job.
 
    d) Review job output for successful load(s).
 
 
+--------------------------------------------------------------------+
| Step 8. Install DVTOC Programs                                     |  
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($INST04)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC004 JOB (SYS),'Install DVTOC',        <-- Review and Modify
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC for MVS3.8J TSO / Hercules                    *
//* *                                                      *
//* *  JOB: $INST04  Install DVTOC Software                *
//* *                                                      *
//* *  - Install libraries marked...                       *
//* *    - Search for '<--TARGET'                          *
//* *    - Update install libraries per your               *
//* *      installation standard                           *
//* *                                                      *
//* -------------------------------------------------------*
//*
//* -------------------------------------------------------*
//* *                                                      *
//* *  PROC: ASMLKED                                       *
//* *       Assembler Link-Edit                            *
//* *                                                      *
//* -------------------------------------------------------*
//ASML     PROC HLQ=WHATHLQ,VRM=VXRXMXX,
//             MBR=WHOWHAT
//*
//ASM      EXEC PGM=IFOX00,
//             PARM='NODECK,LOAD,RENT,TERM,XREF'
//SYSGO    DD  DSN=&&LOADSET,DISP=(MOD,PASS),SPACE=(CYL,(1,1)),
//             UNIT=VIO,DCB=(DSORG=PS,RECFM=FB,LRECL=80,BLKSIZE=800)
//SYSLIB   DD  DSN=SYS1.MACLIB,DISP=SHR
//         DD  DSN=SYS1.AMODGEN,DISP=SHR
//         DD  DSN=SYS2.MACLIB,DISP=SHR          ** YREG  **
//         DD  DSN=&HLQ..&VRM..MACLIB,DISP=SHR   * myMACLIB **
//SYSTERM  DD  SYSOUT=*
//SYSPRINT DD  SYSOUT=*
//SYSPUNCH DD  DSN=NULLFILE
//SYSUT1   DD  UNIT=VIO,SPACE=(CYL,(6,1))
//SYSUT2   DD  UNIT=VIO,SPACE=(CYL,(6,1))
//SYSUT3   DD  UNIT=VIO,SPACE=(CYL,(6,1))
//SYSIN    DD  DSN=&HLQ..&VRM..ASM(&MBR),DISP=SHR <--INPUT
//*
//LKED     EXEC PGM=IEWL,PARM='MAP,LIST,LET,RENT,XREF',
//             COND=(0,NE,ASM)
//SYSLIN   DD  DSN=&&LOADSET,DISP=(OLD,DELETE)
//         DD  DDNAME=SYSIN
//SYSLMOD  DD  DUMMY
//SYSPRINT DD  SYSOUT=*
//SYSUT1   DD  UNIT=VIO,SPACE=(CYL,(5,2))
//SYSIN    DD  DUMMY
//*
//         PEND
//*
//* -------------------------------------------------------*
//* *  Assemble Link-Edit DVTOC to ISPLLIB                 *
//* -------------------------------------------------------*
//DVTOC    EXEC  ASML,HLQ=DVTOC,VRM=V0R9M00,MBR=DVTOC,
//         PARM.LKED='MAP,LIST,LET,RENT,XREF,REUS,REFR'
//LKED.SYSLMOD DD  DISP=SHR,
//         DSN=XXXXXXXX.ISPLLIB(&MBR)              <--TARGET 
//*
//* -------------------------------------------------------*
//* *  Assemble Link-Edit DVTOCFA to ISPLLIB               *
//* -------------------------------------------------------*
//DVTOCFA EXEC   ASML,HLQ=DVTOC,VRM=V0R9M00,MBR=DVTOCFA, 
//         PARM.LKED='MAP,LIST,LET,RENT,XREF,REUS,REFR'
//LKED.SYSLMOD DD  DISP=SHR,
//         DSN=XXXXXXXX.ISPLLIB(&MBR)              <--TARGET 
//*
//* -------------------------------------------------------*
//* *  Assemble Link-Edit DVTOCFS to ISPLLIB               *
//* -------------------------------------------------------*
//DVTOCFS EXEC   ASML,HLQ=DVTOC,VRM=V0R9M00,MBR=DVTOCFS, 
//         PARM.LKED='MAP,LIST,LET,RENT,XREF,REUS,REFR'
//LKED.SYSLMOD DD  DISP=SHR,
//         DSN=XXXXXXXX.ISPLLIB(&MBR)              <--TARGET 
//*
//
______________________________________________________________________
Figure 7: $INST04 JCL
 
 
    a) Member $INST04 installs program(s).
 
       Note:  If no components are included for this distribution,
       -----  an IEFBR14 step is executed.
 
    b) Review and update JOB statement and other JCL to conform to your
       installation standard.                                       
 
    c) Submit the job.
 
    d) Review job output for successful completion.
 
 
+--------------------------------------------------------------------+
| Step 9. Install ISPF parts                                         |
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($INST05)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC005 JOB (SYS),'Install ISPF Parts',   <-- Review and Modify 
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC in MVS3.8J TSO / Hercules                     *
//* *                                                      *
//* *  JOB: $INST05  Install ISPF parts                    *
//* *                                                      *
//* *  Note: Duplicate members are over-written.           *
//* *                                                      *
//* -------------------------------------------------------*
//*
//* -------------------------------------------------------*
//* *                                                      *
//* *  PROC: PARTSISPF                                     *
//* *       Copy ISPF Parts                                *
//* *                                                      *
//* -------------------------------------------------------*
//PARTSI   PROC HLQ=MYHLQ,VRM=VXRXMXX,
//             CLIB='XXXXXXXX.ISPCLIB',    
//             MLIB='XXXXXXXX.ISPMLIB',    
//             PLIB='XXXXXXXX.ISPPLIB',   
//             SLIB='XXXXXXXX.ISPSLIB',   
//             TLIB='XXXXXXXX.ISPTLIB'    
//*
//* -------------------------------------------------------*
//* *                                                      *
//* *  CLIB Member Installation                            *
//* *                                                      *
//* *  Suggested Location:                                 *
//* *      DSN defined or concatenated to ISPCLIB DD       *
//* *                                                      *
//* *  Note: If you use a new PDS, it must be defined      *
//* *        before executing this install job AND the     *
//* *        ISPF start-up procedure should include the    *
//* *        new PDS in the ISPCLIB allocation step.       *
//* *                                                      *
//* -------------------------------------------------------*
//ADDCLIB  EXEC PGM=IEBCOPY              
//SYSPRINT DD  SYSOUT=*
//CLIBIN   DD  DSN=&HLQ..&VRM..ISPF,DISP=SHR             
//CLIBOUT  DD  DSN=&CLIB,DISP=SHR
//SYSIN    DD  DUMMY          
//*
//* -------------------------------------------------------*
//* *                                                      *
//* *  MLIB Member Installation                            *
//* *                                                      *
//* *  Suggested Location:                                 *
//* *      DSN defined or concatenated to ISPMLIB DD       *
//* *                                                      *
//* *  Note: If you use a new PDS, it must be defined      *
//* *        before executing this install job AND the     *
//* *        ISPF start-up procedure should include the    *
//* *        new PDS in the ISPMLIB allocation step.       *
//* *                                                      *
//* -------------------------------------------------------*
//ADDMLIB  EXEC PGM=IEBCOPY              
//SYSPRINT DD  SYSOUT=*
//MLIBIN   DD  DSN=&HLQ..&VRM..ISPF,DISP=SHR             
//MLIBOUT  DD  DSN=&MLIB,DISP=SHR
//SYSIN    DD  DUMMY          
//*
//* -------------------------------------------------------*
//* *                                                      *
//* *  PLIB Member Installation                            *
//* *                                                      *
//* *  Suggested Location:                                 *
//* *      DSN defined or concatenated to ISPPLIB DD       *
//* *                                                      *
//* *  Note: If you use a new PDS, it must be defined      *
//* *        before executing this install job AND the     *
//* *        ISPF start-up procedure should include the    *
//* *        new PDS in the ISPPLIB allocation step.       *
//* *                                                      *
//* -------------------------------------------------------*
//ADDPLIB  EXEC PGM=IEBCOPY              
//SYSPRINT DD  SYSOUT=*
//PLIBIN   DD  DSN=&HLQ..&VRM..ISPF,DISP=SHR             
//PLIBOUT  DD  DSN=&PLIB,DISP=SHR
//SYSIN    DD  DUMMY          
//*
//* -------------------------------------------------------*
//* *                                                      *
//* *  SLIB Member Installation                            *
//* *                                                      *
//* *  Suggested Location:                                 *
//* *      DSN defined or concatenated to ISPSLIB DD       *
//* *                                                      *
//* *  Note: If you use a new PDS, it must be defined      *
//* *        before executing this install job AND the     *
//* *        ISPF start-up procedure should include the    *
//* *        new PDS in the ISPSLIB allocation step.       *
//* *                                                      *
//* -------------------------------------------------------*
//ADDSLIB  EXEC PGM=IEBCOPY              
//SYSPRINT DD  SYSOUT=*
//SLIBIN   DD  DSN=&HLQ..&VRM..ISPF,DISP=SHR             
//SLIBOUT  DD  DSN=&SLIB,DISP=SHR
//SYSIN    DD  DUMMY          
//*
//*
//* -------------------------------------------------------*
//* *                                                      *
//* *  TLIB Member Installation                            *
//* *                                                      *
//* *  Suggested Location:                                 *
//* *      DSN defined or concatenated to ISPTLIB DD       *
//* *                                                      *
//* *  Note: If you use a new PDS, it must be defined      *
//* *        before executing this install job AND the     *
//* *        ISPF start-up procedure should include the    *
//* *        new PDS in the ISPTLIB allocation step.       *
//* *                                                      *
//* -------------------------------------------------------*
//ADDTLIB  EXEC PGM=IEBCOPY              
//SYSPRINT DD  SYSOUT=*
//TLIBIN   DD  DSN=&HLQ..&VRM..ISPF,DISP=SHR             
//TLIBOUT  DD  DSN=&TLIB,DISP=SHR
//SYSIN    DD  DUMMY          
//*
//         PEND
//*
//ISPF     EXEC PARTSI,HLQ=DVTOC,VRM=V0R9M00,
//         CLIB='XXXXXXXX.ISPCLIB',                <--TARGET
//         MLIB='XXXXXXXX.ISPMLIB',                <--TARGET
//         PLIB='XXXXXXXX.ISPPLIB',                <--TARGET
//         SLIB='XXXXXXXX.ISPSLIB',                <--TARGET
//         TLIB='XXXXXXXX.ISPTLIB'                 <--TARGET
//ADDCLIB.SYSIN    DD  *                  CLIB
   COPY INDD=((CLIBIN,R)),OUTDD=CLIBOUT
   SELECT MEMBER=C$DVTOC      
   SELECT MEMBER=C$DVTOCB     
   SELECT MEMBER=CDVTCFL      
   SELECT MEMBER=CDVTCSEL     
   SELECT MEMBER=CDVTCSRT     
//ADDMLIB.SYSIN    DD  *                  MLIB
   COPY INDD=((MLIBIN,R)),OUTDD=MLIBOUT
   SELECT MEMBER=DVTC01 
   SELECT MEMBER=DVTC02 
   SELECT MEMBER=DVTC03 
//ADDPLIB.SYSIN    DD  *                  PLIB
   COPY INDD=((PLIBIN,R)),OUTDD=PLIBOUT
   SELECT MEMBER=HDVTOC0 
   SELECT MEMBER=HDVTOKCX 
   SELECT MEMBER=PDVTOC0  
   SELECT MEMBER=PDVTOC1  
   SELECT MEMBER=PDVTOC2  
   SELECT MEMBER=PDVTOC3  
   SELECT MEMBER=PDVTOC4  
   SELECT MEMBER=PDVTOC5  
   SELECT MEMBER=PDVTOCD  
   SELECT MEMBER=PDVTOCFA 
   SELECT MEMBER=PDVTOCI  
   SELECT MEMBER=PDVTOCR  
   SELECT MEMBER=PDVTOK1  
   SELECT MEMBER=PDVTOK2  
   SELECT MEMBER=PDVTOK3  
   SELECT MEMBER=PDVTOK4  
   SELECT MEMBER=PDVTOK5  
//ADDSLIB.SYSIN    DD  *                  SLIB
   COPY INDD=((SLIBIN,R)),OUTDD=SLIBOUT
   SELECT MEMBER=NO#MBR#                     /*dummy entry no mbrs! */
//ADDTLIB.SYSIN    DD  *                  TLIB
   COPY INDD=((TLIBIN,R)),OUTDD=TLIBOUT
   SELECT MEMBER=NO#MBR#                     /*dummy entry no mbrs! */
//
______________________________________________________________________
Figure 8: $INST05 JCL
 
 
    a) Member $INST05 installs ISPF component(s).
 
       Note:  If no ISPF components are included for this distribution,
       -----  RC = 4 is returned by the corresponding IEBCOPY step.
 
    b) Review and update JOB statement and other JCL to conform to your
       installation standard.                                       
 
    c) Review and update DD statements for ISPCLIB (clist),
       ISPMLIB (messages), and/or ISPPLIB (panel) library names. 
       The DD statements are tagged with '<--TARGET'.
 
    d) Submit the job.
 
    e) Review job output for successful load(s).
 
 
+--------------------------------------------------------------------+
| Step 10. Install Other Software                                    |  
+--------------------------------------------------------------------+
|         JCL Member: DVTOC.V0R9M00.CNTL($INST40)                    |
+--------------------------------------------------------------------+
 
 
______________________________________________________________________
//DVTOC040 JOB (SYS),'Install Other Pgms',   <-- Review and Modify 
//         CLASS=A,MSGCLASS=X,               <-- Review and Modify
//         MSGLEVEL=(1,1),NOTIFY=&SYSUID     <-- Review and Modify
//* -------------------------------------------------------*
//* *  DVTOC in MVS3.8J TSO / Hercules                     *
//* *                                                      *
//* *  JOB: $INST40  Install Other Components              *
//* *       Install xxxxxx   Programs                      *
//* *       **Note: Dummy job, no other programs!          *
//* *                                                      *
//* *                                                      *
//* -------------------------------------------------------*
//*
//* -------------------------------------------------------*
//* *  IEFBR14                                             *
//* -------------------------------------------------------*
//DUMMY    EXEC PGM=IEFBR14
//SYSPRINT DD   SYSOUT=*
// 
______________________________________________________________________
Figure 9: $INST40 JCL
 
 
    a) Member $INST40 installs additional software.
 
       Note:  If no other software is included for this distribution,
       -----  an IEFBR14 step is executed.
 
    b) Review and update JOB statement and other JCL to conform to your
       installation standard.                                       
 
    c) Submit the job.
 
    d) Review job output for successful completion.
 
 
+--------------------------------------------------------------------+
| Step 11. Validate DVTOC                                            |
+--------------------------------------------------------------------+
 
    The purpose of this step is to initiate the VTOC Utility menu      
    and display a VTOC data set list with 'HERC*' partial HLQ.
 
    a) From the ISPF Main Menu, enter the following command:    
 
        TSO C$DVTOC
 
    b) Panel PDVTOC0 is displayed.  Enter the following data,
       see Figure 9a for reference.
 
        1. Enter  V     for COMMAND
        2. Enter  ALL   for Volume
        3. Enter  S     for Position of DSNstr
        4. Enter  HERC  for DSNstr
        5. Enter  space for Display Mode
        6. Enter  N     for Show no DSNs
        7. Enter  Y     for Show CAT
        8. Enter  A     for Sysout Class
        9. Press ENTER
 
________________________________________________________________________________
 ------------------------------  VTOC Utility  ---------------------------------
 COMMAND ===> V                                                         LARRY01 
                                                                        PDVTOC0 
    V  - Display VTOC entries              PV - Print VTOC entries              
    U  - Display Uncatalog VTOC entries    PU - Print Uncatalog VTOC entries    
    F  - DASD Free Space                   D  - DASD UCB List                   
    DD - Display DD/DSN Allocations                                             
                                                                                
 VTOC DSN Search Parameters:                                                    
    Volume       ===> ALL    Full/Prefixed Volume name or ALL                   
    DSNstrPOS    ===> S      Position of DSNstr (S/E/C)                         
    DSNstr       ===> HERC                                                      
                                                                                
 VTOC Processing Parameters:                                                    
    Display Mode ===>        blank-ISPF B-Browse T-Terminal                     
    Show no DSNs ===> N      Display Results when no DSNs (Y/N)                 
    Show CAT     ===> Y      Show DSN Catalogued status (Y/N)                   
    Sysout Class ===> A      For Print requests                                 
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
________________________________________________________________________________
Figure 9a: Sample PDVTOC  VTOC Utility Menu Panel
 
    c) Panel PDVTOK5 is displays with data set list similar to 
       Figure 9b.
        
________________________________________________________________________________
 dd/mm/yy.jjj hh:mm       ----    VTOC Entries    --------------    ROW 1 OF 134
 COMMAND ===>                                                   SCROLL ===> PAGE
                                                                        LARRY01 
                                                                        PDVTOK5 
 PF3-End   PF7-Up   PF8-Down   PF10-Left   PF11-Right                           
 VTOC ALL CAT Lvl=HERC                                       Sorted by: DSN     
 TOTALS -   134 DATA SETS,     4820 TRKS   ALLOC,      895 TRKS   USED          
  VSAM  nonVSAM    ISAM      DA      PO      PS   Other   VSrch                 
 00015    00119   00000   00000   00095   00020   00004   ALL                   
                                                                                
 S   DSN----------------------------------------- CAT VOLUME DSO ALLOC  PCT  EX 
     HERC01.ACCT.OUT                              C   PUB000 PS      1  100   1 
     HERC01.BRX370.EXEC                           C   PUB007 PO     45    4   1 
     HERC01.CCOMPR.CNTL                           C   PUB007 PO    100    9   1 
     HERC01.CHKDSN.CNTL                           C   PUB007 PO    100   32   1 
     HERC01.CHKDSN2.CNTL                          C   PUB007 PO    100    5   1 
     HERC01.CMDPROC                               C   MVSCAT PO     15    6   1 
     HERC01.CONDENSE                              C   XMIT00 PS    579   30   1 
     HERC01.EMP.DATA                              C   PUB007 PS      5   20   1 
     HERC01.FPDS0001.CNTL                         C   PUB000 PS     60    3   1 
     HERC01.IMREPORT                              C   TSO00A        45    0   1 
     HERC01.ISP.PROF                              C   PUB000 PO     30   66   1 
     HERC01.ISPTBLS.V1R0M00.CNTL                  C   PUB000 PO     20   20   1 
________________________________________________________________________________
Figure 9b: Sample PDVTOK5 VTOC Entries Panel (partial list)
 
 
 
    d) Use PF7/PF8 for Page Up and Page Down scrolling.    
 
    e) Use PF10/PF11 vary the VTOC Listing View.    
       Each view of the five, displays diffent data set attributes.
       Default view is PDVTOK5 or PDVTOC5.                       
 
    f) Select on of the data sets with a selection code of B to
       browse the data set.
 
    g) Use PF3 until the ISPF Main Menu is displayed.                   
 
    h) Validation for VTOC utility is complete.
 
    i) Provided other software is installed on your sytem, other DVTOC   
       menu options can be exercised such as PRINT VTOC.  
 
 
+--------------------------------------------------------------------+
| Step 12. Done                                                      |
+--------------------------------------------------------------------+
 
 
    a) Congratulations!  You completed the installation for DVTOC.


+--------------------------------------------------------------------+
| Step 13. Incorporate DVTOC into ISPF UTILITY SELECTION Menu        |
+--------------------------------------------------------------------+
 
 
    a) To integrate DVTOC into your ISPF system, refer to
       DVTOC.V0R9M00.ASM(DVTOC) for suggested steps in the Overview
       section as a menu item or ISPF command.                      
 
       
                                                                            
                                                                            



Enjoy DVTOC for ISPF 2.x on MVS 3.8J!
                                                                            

======================================================================
* IV. S o f t w a r e   I n v e n t o r y   L i s t                  |
======================================================================

  - DVTOC.V0R9M00.ASM 
   . DVTOC       TSO CP VTOC Display
   . DVTOCFA     Allocate/Deallocate File Subroutine
   . DVTOCFS     DSCB-4 Volume Information Subroutine
      
  - DVTOC.V0R9M00.CLIST
   . README      Dummy member, this is intentional

  - DVTOC.V0R9M00.CNTL
   . $INST00     Define Alias for HLQ DVTOC       
   . $INST01     Load CNTL data set from distribution tape (HET)
   . $INST02     Load other data sets from distribution tape (HET)
   . $INST03     Install TSO Parts
   . $INST04     Install DVTOC CP and utilities
   . $INST05     Install ISPF Parts
   . $INST40     Install Other programs                  
   . $RECVXMI    Receive XMI SEQ to MVS PDSs via RECV370
   . $UP0900     Upgrade to V0R9M00   from   V0R9M00 (IEFBR14)
   . DSCLAIMR    Disclaimer
   . PREREQS     Required User-mods
   . README      Documentation and Installation instructions

  - DVTOC.V0R9M00.HELP
   . README      Dummy member, this is intentional

  - DVTOC.V0R9M00.ISPF
   . PDVTOCD     VTOC Dataset Action Panel (Delete,Uncat, Catlg, Scratch)
   . PDVTOCFA    VTOC Display Dataset Attributes Panel
   . PDVTOCI     VTOC Dataset Information Panel
   . PDVTOCR     VTOC Dataset Rename Panel
   . PDVTOC0     VTOC Utility Menu
   . HDVTOC0     VTOC Utilitm Menu (HELP)
   . PDVTOC1     VTOC Dataset List Panel 1 (w/Volume Summary)
   . PDVTOK1     VTOC Dataset List Panel 1
   . PDVTOC2     VTOC Dataset List Panel 2 (w/Volume Summary)
   . PDVTOK2     VTOC Dataset List Panel 2
   . PDVTOC3     VTOC Dataset List Panel 3 (w/Volume Summary)
   . PDVTOK3     VTOC Dataset List Panel 3
   . PDVTOC4     VTOC Dataset List Panel 4 (w/Volume Summary)
   . PDVTOK4     VTOC Dataset List Panel 4
   . PDVTOC5     VTOC Dataset List Panel 5 (w/Volume Summary)
   . PDVTOK5     VTOC Dataset List Panel 5
   . HDVTOKCX    VTOC Dataset List (HELP)
   . C$DVTOC     IVP DVTOC          CLIST   
   . C$DVTOCB    DVTOC Ext API      CLIST   
   . CDVTCFL     Find/Locate        CLIST
   . CDVTCSEL    Select Processor   CLIST
   . CDVTCSRT    Sort Display       CLIST
   . DVTC01      Messages                  
   . DVTC02      Messages                  
   . DVTC03      Messages                  
                
  - DVTOC.V0R9M00.MACLIB
   . DVCTBL      Device Table Entries
   . ISPFPL      ISPF Parameter Address List (10)       
 $ . ISPFSRV     ISPF Service keywords                
 $ . LA#ST       Load Address and Store
   . LBISPL      Call to ISPLINK (LarryB version)      
   . MISCDC      Constants for double-quotes and Apostrophe
   . MOVEC       Move VAR at R6, len reflected in R8 (requires MOVEI)
   . MOVEI       Init R6 w/ addr of VAR, init R8 to 0
   . MOVER       Move VAR at R6 until BLANK is found         
   . MOVEV       Move VAR at R6                      
   . RDTECOMA    DateTime comm area                   
   . RDTECOMC    DateTime comm area (COBOL)          
   . RTRIM       Remove trailing spaces          
   . SVC78A      SVC78 message area
       
       
  - After downloading any other required software, consult provided
    documentation including any configuration steps (if applicable)
    for software and HELP file installation. 
       
       
 $ - Denotes modified software component for THIS DISTRIBUTION               
     relative to prior DISTRIBUTION               
       
       
                                                                            
